Energy Performance Certificate
Park View, Royal Masonic School for Girls, Rickmansworth Park, WD3 4HF
Energy rating
Current: 53 E | Potential: 101 A
Environmental impact (CO₂)
Current: 55
| Potential: 102
| Field | Value |
|---|---|
| LMK KEY | 9732-6824-6000-0253-3206 |
| ADDRESS1 | Park View |
| ADDRESS2 | Royal Masonic School for Girls |
| ADDRESS3 | Rickmansworth Park |
| POSTCODE | WD3 4HF |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | A |
| CURRENT ENERGY EFFICIENCY | 53 |
| POTENTIAL ENERGY EFFICIENCY | 101 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2022-04-07 |
| LOCAL AUTHORITY | E07000102 |
| CONSTITUENCY | E14001496 |
| COUNTY | — |
| LODGEMENT DATE | 2022-05-19 |
| TRANSACTION TYPE | Stock condition survey |
| ENVIRONMENT IMPACT CURRENT | 55 |
| ENVIRONMENT IMPACT POTENTIAL | 102 |
| ENERGY CONSUMPTION CURRENT | 326 |
| ENERGY CONSUMPTION POTENTIAL | -7 |
| CO2 EMISSIONS CURRENT | 4.3 |
| CO2 EMISS CURR PER FLOOR AREA | 48 |
| CO2 EMISSIONS POTENTIAL | -0.4 |
| LIGHTING COST CURRENT | 72 |
| LIGHTING COST POTENTIAL | 73 |
| HEATING COST CURRENT | 959 |
| HEATING COST POTENTIAL | 558 |
| HOT WATER COST CURRENT | 79 |
| HOT WATER COST POTENTIAL | 53 |
| TOTAL FLOOR AREA | 88 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 4 |
| NUMBER HEATED ROOMS | 4 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 1 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, wood logs |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Park View, Royal Masonic School for Girls, Rickmansworth Park |
| LOCAL AUTHORITY LABEL | Three Rivers |
| CONSTITUENCY LABEL | South West Hertfordshire |
| POSTTOWN | RICKMANSWORTH |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2022-05-19 10:25:12 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 10 |
| UPRN | 200000939110 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 2 |
| Source file | certificates-2022.csv |
| COUNTRY | England |
| REGION | E12000006 |
| Address display | — |
| Nation | ew |