Energy Performance Certificate

28, Heather Gardens, MK41 0TD

EPC Report

Energy rating

Current: 64 D | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 45 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 75 Potential: 75
Field Value
LMK KEY 9718-9017-6287-6420-1284
ADDRESS1 28, Heather Gardens
ADDRESS2
ADDRESS3
POSTCODE MK41 0TD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2020-03-19
LOCAL AUTHORITY E06000055
CONSTITUENCY E14001084
COUNTY
LODGEMENT DATE 2020-03-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 524
ENERGY CONSUMPTION POTENTIAL 205
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 35
HEATING COST CURRENT 479
HEATING COST POTENTIAL 336
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 37
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Heather Gardens
LOCAL AUTHORITY LABEL Bedford
CONSTITUENCY LABEL Bedford
POSTTOWN BEDFORD
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2020-03-20 16:47:10
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100080018784
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000006
Address display
Nation ew