Energy Performance Certificate

Flat B, 125 Myddleton Road, N22 8NG

EPC Report

Energy rating

Current: 25 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 34 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 74 Potential: 74
Field Value
LMK KEY 9718-0055-7249-4193-5930
ADDRESS1 Flat B
ADDRESS2 125 Myddleton Road
ADDRESS3
POSTCODE N22 8NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2017-01-19
LOCAL AUTHORITY E09000014
CONSTITUENCY E14001503
COUNTY
LODGEMENT DATE 2017-01-19
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 1292
ENERGY CONSUMPTION POTENTIAL 444
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 224
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 15
LIGHTING COST POTENTIAL 15
HEATING COST CURRENT 524
HEATING COST POTENTIAL 199
HOT WATER COST CURRENT 296
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 14
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 1.5
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat B, 125 Myddleton Road
LOCAL AUTHORITY LABEL Haringey
CONSTITUENCY LABEL Southgate and Wood Green
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-01-19 13:35:09
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 2
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10003983480
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew