Energy Performance Certificate

Flat 58 Royal Swan Quarter, Leret Way, KT22 7JL

EPC Report

Energy rating

Current: 70 C | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 50 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 50 Potential: 50
Field Value
LMK KEY 9718-0032-6262-5820-3284
ADDRESS1 Flat 58 Royal Swan Quarter
ADDRESS2 Leret Way
ADDRESS3
POSTCODE KT22 7JL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-02-19
LOCAL AUTHORITY E07000210
CONSTITUENCY E14001227
COUNTY
LODGEMENT DATE 2020-02-19
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 316
ENERGY CONSUMPTION POTENTIAL 316
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 82
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 617
HEATING COST POTENTIAL 617
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 193
TOTAL FLOOR AREA 86
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.15
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 58 Royal Swan Quarter, Leret Way
LOCAL AUTHORITY LABEL Mole Valley
CONSTITUENCY LABEL Epsom and Ewell
POSTTOWN LEATHERHEAD
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2020-02-19 15:43:38
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 10000822730
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew