Energy Performance Certificate

39 Kingfisher Drive, YO22 4DY

EPC Report

Energy rating

Current: 79 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 78 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 87 Potential: 87
Field Value
LMK KEY 9710-3047-6202-4405-0200
ADDRESS1 39 Kingfisher Drive
ADDRESS2
ADDRESS3
POSTCODE YO22 4DY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-02-19
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001461
COUNTY
LODGEMENT DATE 2025-02-19
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 135
ENERGY CONSUMPTION POTENTIAL 80
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 176
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 728
HEATING COST POTENTIAL 740
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 98
TOTAL FLOOR AREA 137
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 59
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 59% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39 Kingfisher Drive
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Scarborough and Whitby
POSTTOWN WHITBY
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2025-02-19 21:12:14
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 10090177601
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000003
Address display
Nation ew