Energy Performance Certificate

34, The Paddocks, Yarnton, OX5 1TF

EPC Report

Energy rating

Current: 38 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 46 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 88 Potential: 88
Field Value
LMK KEY 9708-2030-7232-1894-5950
ADDRESS1 34, The Paddocks
ADDRESS2 Yarnton
ADDRESS3
POSTCODE OX5 1TF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-02-10
LOCAL AUTHORITY E07000177
CONSTITUENCY E14001090
COUNTY
LODGEMENT DATE 2014-02-10
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 361
ENERGY CONSUMPTION POTENTIAL 66
CO2 EMISSIONS CURRENT 4.5
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1103
HEATING COST POTENTIAL 400
HOT WATER COST CURRENT 99
HOT WATER COST POTENTIAL 63
TOTAL FLOOR AREA 69
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 40
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34, The Paddocks, Yarnton
LOCAL AUTHORITY LABEL Cherwell
CONSTITUENCY LABEL Bicester and Woodstock
POSTTOWN KIDLINGTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2014-02-10 16:13:26
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100120794349
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew