Energy Performance Certificate

Tegfan, Llechryd, SA43 2NH

EPC Report

Energy rating

Current: 21 F | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 32 | Potential: 96
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 96 Potential: 96
Field Value
LMK KEY 9708-0997-7200-4436-8960
ADDRESS1 Tegfan
ADDRESS2 Llechryd
ADDRESS3
POSTCODE SA43 2NH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-10-10
LOCAL AUTHORITY W06000008
CONSTITUENCY W07000093
COUNTY
LODGEMENT DATE 2016-10-24
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 96
ENERGY CONSUMPTION CURRENT 488
ENERGY CONSUMPTION POTENTIAL 8
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 82
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 1783
HEATING COST POTENTIAL 665
HOT WATER COST CURRENT 260
HOT WATER COST POTENTIAL 156
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Tegfan, Llechryd
LOCAL AUTHORITY LABEL Ceredigion
CONSTITUENCY LABEL Ceredigion Preseli
POSTTOWN CARDIGAN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-10-24 15:24:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 49043762
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew