Energy Performance Certificate

3, Chapel Walk, Didmarton, GL9 1DR

EPC Report

Energy rating

Current: 39 E | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 20 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 65 Potential: 65
Field Value
LMK KEY 9700-2830-7028-9792-3605
ADDRESS1 3, Chapel Walk
ADDRESS2 Didmarton
ADDRESS3
POSTCODE GL9 1DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2012-12-10
LOCAL AUTHORITY E07000079
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2012-12-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 738
ENERGY CONSUMPTION POTENTIAL 228
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 133
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 48
LIGHTING COST POTENTIAL 35
HEATING COST CURRENT 760
HEATING COST POTENTIAL 333
HOT WATER COST CURRENT 188
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 54
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 25
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.97
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Chapel Walk, Didmarton
LOCAL AUTHORITY LABEL Cotswold
CONSTITUENCY LABEL South Cotswolds
POSTTOWN BADMINTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-12-10 18:48:20
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10006831934
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew