Energy Performance Certificate

40, Derwent Way, Great Notley, CM77 7UX

EPC Report

Energy rating

Current: 65 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 65 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 92 Potential: 92
Field Value
LMK KEY 9683-2809-6696-9004-8761
ADDRESS1 40, Derwent Way
ADDRESS2 Great Notley
ADDRESS3
POSTCODE CM77 7UX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-11-01
LOCAL AUTHORITY E07000067
CONSTITUENCY E14001121
COUNTY
LODGEMENT DATE 2014-11-02
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 240
ENERGY CONSUMPTION POTENTIAL 40
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 432
HEATING COST POTENTIAL 337
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 57
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40, Derwent Way, Great Notley
LOCAL AUTHORITY LABEL Braintree
CONSTITUENCY LABEL Braintree
POSTTOWN BRAINTREE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2014-11-02 13:39:28
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100090297414
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew