Energy Performance Certificate

23, Haley Court, HX3 6DE

EPC Report

Energy rating

Current: 67 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 56 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 67 Potential: 67
Field Value
LMK KEY 9667-2876-7602-9291-6151
ADDRESS1 23, Haley Court
ADDRESS2
ADDRESS3
POSTCODE HX3 6DE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2019-10-16
LOCAL AUTHORITY E08000033
CONSTITUENCY E14001262
COUNTY
LODGEMENT DATE 2019-10-16
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 339
ENERGY CONSUMPTION POTENTIAL 255
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 494
HEATING COST POTENTIAL 315
HOT WATER COST CURRENT 312
HOT WATER COST POTENTIAL 170
TOTAL FLOOR AREA 67
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 10.1
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Haley Court
LOCAL AUTHORITY LABEL Calderdale
CONSTITUENCY LABEL Halifax
POSTTOWN HALIFAX
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-10-16 15:40:26
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10034477256
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000003
Address display