Energy Performance Certificate

49a Claremont Road, CV21 3LX

EPC Report

Energy rating

Current: 42 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 26 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 63 Potential: 63
Field Value
LMK KEY 9648-0099-6293-9650-0284
ADDRESS1 49a Claremont Road
ADDRESS2
ADDRESS3
POSTCODE CV21 3LX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2020-07-14
LOCAL AUTHORITY E07000220
CONSTITUENCY E14001453
COUNTY
LODGEMENT DATE 2020-07-14
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 835
ENERGY CONSUMPTION POTENTIAL 326
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 141
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 954
HEATING COST POTENTIAL 544
HOT WATER COST CURRENT 197
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 40
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 49a Claremont Road
LOCAL AUTHORITY LABEL Rugby
CONSTITUENCY LABEL Rugby
POSTTOWN RUGBY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-07-14 19:54:55
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10010511754
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000005
Address display
Nation ew