Energy Performance Certificate

47 HARLOW MOOR DRIVE, HG2 0LE

EPC Report

Energy rating

Current: 26 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 F Current: 26 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 14 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 Current: 14 57 Potential: 57
Field Value
LMK KEY 9645-1005-4203-9839-0200
ADDRESS1 47 HARLOW MOOR DRIVE
ADDRESS2
ADDRESS3
POSTCODE HG2 0LE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 26
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-07-14
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001269
COUNTY
LODGEMENT DATE 2021-07-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 14
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 607
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 20
CO2 EMISS CURR PER FLOOR AREA 122
CO2 EMISSIONS POTENTIAL 7.4
LIGHTING COST CURRENT 207
LIGHTING COST POTENTIAL 116
HEATING COST CURRENT 3045
HEATING COST POTENTIAL 1274
HOT WATER COST CURRENT 434
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 168
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas, Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.75
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47 HARLOW MOOR DRIVE
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Harrogate and Knaresborough
POSTTOWN HARROGATE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-07-14 18:21:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100050394524
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew