Energy Performance Certificate

33 Gilston Road, SW10 9SJ

EPC Report

Energy rating

Current: 55 D | Potential: 56 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 56 D Potential: 56 D

Environmental impact (CO₂)

Current: 59 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 61 Potential: 61
Field Value
LMK KEY 9643-3944-5209-3044-3204
ADDRESS1 33 Gilston Road
ADDRESS2
ADDRESS3
POSTCODE SW10 9SJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 56
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-11-14
LOCAL AUTHORITY E09000020
CONSTITUENCY E14001160
COUNTY
LODGEMENT DATE 2024-11-21
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 148
ENERGY CONSUMPTION POTENTIAL 140
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 16
LIGHTING COST CURRENT 322
LIGHTING COST POTENTIAL 322
HEATING COST CURRENT 7567
HEATING COST POTENTIAL 7567
HOT WATER COST CURRENT 466
HOT WATER COST POTENTIAL 466
TOTAL FLOOR AREA 690
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 14
NUMBER HEATED ROOMS 14
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.21
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33 Gilston Road
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Chelsea and Fulham
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-11-21 09:07:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 120
LOW ENERGY FIXED LIGHT COUNT 120
UPRN 217033737
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew