Energy Performance Certificate

43 Hervey Road, SE3 8BS

EPC Report

Energy rating

Current: 60 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 48 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 74 Potential: 74
Field Value
LMK KEY 9639-3629-8109-0776-1226
ADDRESS1 43 Hervey Road
ADDRESS2
ADDRESS3
POSTCODE SE3 8BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-11-26
LOCAL AUTHORITY E09000011
CONSTITUENCY E14001223
COUNTY
LODGEMENT DATE 2021-11-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 223
ENERGY CONSUMPTION POTENTIAL 102
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 126
LIGHTING COST POTENTIAL 129
HEATING COST CURRENT 1576
HEATING COST POTENTIAL 859
HOT WATER COST CURRENT 102
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 238
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 43 Hervey Road
LOCAL AUTHORITY LABEL Greenwich
CONSTITUENCY LABEL Eltham and Chislehurst
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-11-26 11:05:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 100020974745
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew