Energy Performance Certificate

9 Pembroke Court, LA9 5JA

EPC Report

Energy rating

Current: 52 E | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 83 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 86 Potential: 86
Field Value
LMK KEY 9635-3029-2209-0873-7292
ADDRESS1 9 Pembroke Court
ADDRESS2
ADDRESS3
POSTCODE LA9 5JA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2025-11-17
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001580
COUNTY
LODGEMENT DATE 2025-11-20
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 232
ENERGY CONSUMPTION POTENTIAL 181
CO2 EMISSIONS CURRENT 1.5
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1393
HEATING COST POTENTIAL 967
HOT WATER COST CURRENT 909
HOT WATER COST POTENTIAL 909
TOTAL FLOOR AREA 72
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.7
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION positive input from outside
ADDRESS 9 Pembroke Court
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Westmorland and Lonsdale
POSTTOWN KENDAL
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2025-11-20 18:31:45
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100110342870
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000002
Address display
Nation ew