Energy Performance Certificate

3 Homewood, 41, Lilley Road, L7 0LP

EPC Report

Energy rating

Current: 59 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 57 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 67 Potential: 67
Field Value
LMK KEY 9628-4090-6237-6800-3264
ADDRESS1 3 Homewood
ADDRESS2 41, Lilley Road
ADDRESS3
POSTCODE L7 0LP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-03-12
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001340
COUNTY
LODGEMENT DATE 2020-03-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 384
ENERGY CONSUMPTION POTENTIAL 295
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 450
HEATING COST POTENTIAL 357
HOT WATER COST CURRENT 78
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 36
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Less Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Homewood, 41, Lilley Road
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Wavertree
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-03-12 10:40:04
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 38240357
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew