Energy Performance Certificate

1, Town Close, Fulbourn, CB21 5DN

EPC Report

Energy rating

Current: 28 F | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 2 | Potential: 36
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 2 Current: 2 36 Potential: 36
Field Value
LMK KEY 9618-9090-7279-4016-9990
ADDRESS1 1, Town Close
ADDRESS2 Fulbourn
ADDRESS3
POSTCODE CB21 5DN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-01-19
LOCAL AUTHORITY E07000012
CONSTITUENCY E14001481
COUNTY
LODGEMENT DATE 2016-01-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 2
ENVIRONMENT IMPACT POTENTIAL 36
ENERGY CONSUMPTION CURRENT 871
ENERGY CONSUMPTION POTENTIAL 405
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 171
CO2 EMISSIONS POTENTIAL 7.0
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1662
HEATING COST POTENTIAL 697
HOT WATER COST CURRENT 341
HOT WATER COST POTENTIAL 341
TOTAL FLOOR AREA 93
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 70
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 70% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Town Close, Fulbourn
LOCAL AUTHORITY LABEL South Cambridgeshire
CONSTITUENCY LABEL South Cambridgeshire
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-01-20 10:26:09
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100090162444
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew