Energy Performance Certificate

158 Ratcliffe Road, Sileby, LE12 7QA

EPC Report

Energy rating

Current: 24 F | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 26 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 70 Potential: 70
Field Value
LMK KEY 9600-0253-0422-7221-3473
ADDRESS1 158 Ratcliffe Road
ADDRESS2 Sileby
ADDRESS3
POSTCODE LE12 7QA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2023-04-25
LOCAL AUTHORITY E07000130
CONSTITUENCY E14001357
COUNTY
LODGEMENT DATE 2023-04-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 699
ENERGY CONSUMPTION POTENTIAL 250
CO2 EMISSIONS CURRENT 7.7
CO2 EMISS CURR PER FLOOR AREA 112
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 123
LIGHTING COST POTENTIAL 123
HEATING COST CURRENT 3253
HEATING COST POTENTIAL 1771
HOT WATER COST CURRENT 705
HOT WATER COST POTENTIAL 164
TOTAL FLOOR AREA 68
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 89
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 158 Ratcliffe Road, Sileby
LOCAL AUTHORITY LABEL Charnwood
CONSTITUENCY LABEL Melton and Syston
POSTTOWN LOUGHBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2023-04-26 14:29:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100030459161
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000004
Address display
Nation ew