Energy Performance Certificate

Mansel Court Farmhouse, Mansel Lacy, HR4 7HQ

EPC Report

Energy rating

Current: 58 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 49 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 77 Potential: 77
Field Value
LMK KEY 9598-4028-7243-3133-0914
ADDRESS1 Mansel Court Farmhouse
ADDRESS2 Mansel Lacy
ADDRESS3
POSTCODE HR4 7HQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-07-11
LOCAL AUTHORITY E06000019
CONSTITUENCY E14001395
COUNTY
LODGEMENT DATE 2017-07-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 158
ENERGY CONSUMPTION POTENTIAL 49
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 6.1
LIGHTING COST CURRENT 213
LIGHTING COST POTENTIAL 133
HEATING COST CURRENT 1730
HEATING COST POTENTIAL 1035
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 358
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Mansel Court Farmhouse, Mansel Lacy
LOCAL AUTHORITY LABEL Herefordshire, County of
CONSTITUENCY LABEL North Herefordshire
POSTTOWN HEREFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-07-11 12:32:24
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10009562742
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display
Nation ew