Energy Performance Certificate

18, Spring Clough, OL7 9TJ

EPC Report

Energy rating

Current: 54 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 47 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 77 Potential: 77
Field Value
LMK KEY 9588-5083-7278-3335-7950
ADDRESS1 18, Spring Clough
ADDRESS2
ADDRESS3
POSTCODE OL7 9TJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-08-18
LOCAL AUTHORITY E08000008
CONSTITUENCY E14001070
COUNTY
LODGEMENT DATE 2015-08-25
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 361
ENERGY CONSUMPTION POTENTIAL 149
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 940
HEATING COST POTENTIAL 583
HOT WATER COST CURRENT 104
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 48
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 48% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18, Spring Clough
LOCAL AUTHORITY LABEL Tameside
CONSTITUENCY LABEL Ashton-under-Lyne
POSTTOWN ASHTON-UNDER-LYNE
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2015-08-25 10:06:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 200004433212
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew