Energy Performance Certificate

6, Hillside Cottages, Dolgarrog, LL32 8JP

EPC Report

Energy rating

Current: 13 G | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 G Current: 13 G 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 26 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 94 Potential: 94
Field Value
LMK KEY 9578-5032-6239-4753-7940
ADDRESS1 6, Hillside Cottages
ADDRESS2 Dolgarrog
ADDRESS3
POSTCODE LL32 8JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 13
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-01-13
LOCAL AUTHORITY W06000003
CONSTITUENCY W07000083
COUNTY
LODGEMENT DATE 2017-01-16
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 384
ENERGY CONSUMPTION POTENTIAL -33
CO2 EMISSIONS CURRENT 8.9
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 121
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 2033
HEATING COST POTENTIAL 742
HOT WATER COST CURRENT 169
HOT WATER COST POTENTIAL 104
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Hillside Cottages, Dolgarrog
LOCAL AUTHORITY LABEL Conwy
CONSTITUENCY LABEL Bangor Aberconwy
POSTTOWN CONWY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-01-16 10:25:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100426054
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew