Energy Performance Certificate

2a, Onley Street, NR2 2EB

EPC Report

Energy rating

Current: 78 C | Potential: 96 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 96 A Potential: 96 A

Environmental impact (CO₂)

Current: 82 | Potential: 99
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 99 Potential: 99
Field Value
LMK KEY 9565-3801-7705-9998-3571
ADDRESS1 2a, Onley Street
ADDRESS2
ADDRESS3
POSTCODE NR2 2EB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 96
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2018-10-19
LOCAL AUTHORITY E07000148
CONSTITUENCY E14001409
COUNTY
LODGEMENT DATE 2018-10-19
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 99
ENERGY CONSUMPTION CURRENT 164
ENERGY CONSUMPTION POTENTIAL -6
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 0.0
LIGHTING COST CURRENT 30
LIGHTING COST POTENTIAL 30
HEATING COST CURRENT 209
HEATING COST POTENTIAL 209
HOT WATER COST CURRENT 63
HOT WATER COST POTENTIAL 40
TOTAL FLOOR AREA 37
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.17 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.76
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2a, Onley Street
LOCAL AUTHORITY LABEL Norwich
CONSTITUENCY LABEL Norwich South
POSTTOWN NORWICH
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2018-10-19 14:16:30
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10093500014
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display
Nation ew