Energy Performance Certificate

Balloch, Clifton Road, SO15 4GX

EPC Report

Energy rating

Current: 4 G | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 4 G Current: 4 G 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 9 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 9 Current: 9 80 Potential: 80
Field Value
LMK KEY 9549-2883-7191-9596-9021
ADDRESS1 Balloch
ADDRESS2 Clifton Road
ADDRESS3
POSTCODE SO15 4GX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 4
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-11-17
LOCAL AUTHORITY E06000045
CONSTITUENCY E14001500
COUNTY
LODGEMENT DATE 2016-12-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 9
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 583
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 121
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 2433
HEATING COST POTENTIAL 464
HOT WATER COST CURRENT 347
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 102
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 17
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 23
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 12 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 23% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.52
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Balloch, Clifton Road
LOCAL AUTHORITY LABEL Southampton
CONSTITUENCY LABEL Southampton Test
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-12-07 10:22:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 3
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew