Energy Performance Certificate

65, Manaton Close, SE15 3PW

EPC Report

Energy rating

Current: 59 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 49 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 69 Potential: 69
Field Value
LMK KEY 9548-2888-7296-9596-0235
ADDRESS1 65, Manaton Close
ADDRESS2
ADDRESS3
POSTCODE SE15 3PW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-11-18
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001421
COUNTY
LODGEMENT DATE 2016-11-18
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 253
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 827
HEATING COST POTENTIAL 647
HOT WATER COST CURRENT 140
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 110
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Flat rate charging, no thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, no thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 65, Manaton Close
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Peckham
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2016-11-18 18:46:47
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200003388057
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew