Energy Performance Certificate

23, Barnfield Road, Tean, ST10 4LA

EPC Report

Energy rating

Current: 29 F | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 39 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 81 Potential: 81
Field Value
LMK KEY 9548-2879-7290-9906-5925
ADDRESS1 23, Barnfield Road
ADDRESS2 Tean
ADDRESS3
POSTCODE ST10 4LA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-11-01
LOCAL AUTHORITY E07000198
CONSTITUENCY E14001522
COUNTY
LODGEMENT DATE 2016-11-01
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 512
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 87
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 1389
HEATING COST POTENTIAL 718
HOT WATER COST CURRENT 316
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 70
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas, Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Barnfield Road, Tean
LOCAL AUTHORITY LABEL Staffordshire Moorlands
CONSTITUENCY LABEL Stoke-on-Trent South
POSTTOWN STOKE-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2016-11-01 20:40:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100031844323
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew