Energy Performance Certificate

11 Eastgate Close, SE28 8PJ

EPC Report

Energy rating

Current: 31 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 42 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 66 Potential: 66
Field Value
LMK KEY 9542-3945-9202-9874-0200
ADDRESS1 11 Eastgate Close
ADDRESS2
ADDRESS3
POSTCODE SE28 8PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2024-12-14
LOCAL AUTHORITY E09000004
CONSTITUENCY E14001229
COUNTY
LODGEMENT DATE 2024-12-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 424
ENERGY CONSUMPTION POTENTIAL 211
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 1787
HEATING COST POTENTIAL 674
HOT WATER COST CURRENT 290
HOT WATER COST POTENTIAL 144
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric ceiling heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11 Eastgate Close
LOCAL AUTHORITY LABEL Bexley
CONSTITUENCY LABEL Erith and Thamesmead
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2024-12-15 10:41:28
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100020239988
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew