Energy Performance Certificate

16B Chaucer Avenue, DN17 1PH

EPC Report

Energy rating

Current: 107 A | Potential: 108 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 107 A Current: 107 A 108 A Potential: 108 A

Environmental impact (CO₂)

Current: 106 | Potential: 108
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 106 Current: 106 108 Potential: 108
Field Value
LMK KEY 9537-5137-8000-0868-5222
ADDRESS1 16B Chaucer Avenue
ADDRESS2
ADDRESS3
POSTCODE DN17 1PH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 107
POTENTIAL ENERGY EFFICIENCY 108
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-03-28
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001462
COUNTY
LODGEMENT DATE 2023-03-28
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 106
ENVIRONMENT IMPACT POTENTIAL 108
ENERGY CONSUMPTION CURRENT -45
ENERGY CONSUMPTION POTENTIAL -53
CO2 EMISSIONS CURRENT -0.7
CO2 EMISS CURR PER FLOOR AREA -8
CO2 EMISSIONS POTENTIAL -0.8
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 144
HEATING COST CURRENT 392
HEATING COST POTENTIAL 393
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 162
TOTAL FLOOR AREA 94
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 16B Chaucer Avenue
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Scunthorpe
POSTTOWN Scunthorpe
CONSTRUCTION AGE BAND 2023
LODGEMENT DATETIME 2023-03-28 09:42:49
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10096433934
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000003
Address display
Nation ew