Energy Performance Certificate

4 Newman Close, Westerleigh, BS37 8QT

EPC Report

Energy rating

Current: 71 C | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 74 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 95 Potential: 95
Field Value
LMK KEY 9529-3040-2206-0214-5200
ADDRESS1 4 Newman Close
ADDRESS2 Westerleigh
ADDRESS3
POSTCODE BS37 8QT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2024-06-12
LOCAL AUTHORITY E06000025
CONSTITUENCY E14001545
COUNTY
LODGEMENT DATE 2024-07-31
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 237
ENERGY CONSUMPTION POTENTIAL 30
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 484
HEATING COST POTENTIAL 370
HOT WATER COST CURRENT 335
HOT WATER COST POTENTIAL 218
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Newman Close, Westerleigh
LOCAL AUTHORITY LABEL South Gloucestershire
CONSTITUENCY LABEL Thornbury and Yate
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-07-31 11:43:37
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 553959
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display