Energy Performance Certificate

6, Bridge Terrace, Rawcliffe Bridge, DN14 8PL

EPC Report

Energy rating

Current: 70 C | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 67 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 86 Potential: 86
Field Value
LMK KEY 9502-2838-7322-9992-4171
ADDRESS1 6, Bridge Terrace
ADDRESS2 Rawcliffe Bridge
ADDRESS3
POSTCODE DN14 8PL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-12-18
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001250
COUNTY
LODGEMENT DATE 2012-12-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 176
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 656
HEATING COST POTENTIAL 462
HOT WATER COST CURRENT 94
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 115
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Bridge Terrace, Rawcliffe Bridge
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Goole and Pocklington
POSTTOWN GOOLE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-12-18 12:55:51
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 200000627290
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display