Energy Performance Certificate

33, Valley View Road, Paulton, BS39 7QA

EPC Report

Energy rating

Current: 43 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 40 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 74 Potential: 74
Field Value
LMK KEY 9490-2859-6891-9394-0715
ADDRESS1 33, Valley View Road
ADDRESS2 Paulton
ADDRESS3
POSTCODE BS39 7QA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2014-11-11
LOCAL AUTHORITY E06000022
CONSTITUENCY E14001394
COUNTY
LODGEMENT DATE 2014-11-11
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 392
ENERGY CONSUMPTION POTENTIAL 140
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 841
HEATING COST POTENTIAL 600
HOT WATER COST CURRENT 237
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, Valley View Road, Paulton
LOCAL AUTHORITY LABEL Bath and North East Somerset
CONSTITUENCY LABEL North East Somerset and Hanham
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-11-11 12:20:09
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100120041389
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display
Nation ew