Energy Performance Certificate

26, Walnut Close, NP22 4FF

EPC Report

Energy rating

Current: 80 C | Potential: 116 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 116 A Potential: 116 A

Environmental impact (CO₂)

Current: 82 | Potential: 115
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 115 Potential: 115
Field Value
LMK KEY 9478-6004-7397-4136-2920
ADDRESS1 26, Walnut Close
ADDRESS2
ADDRESS3
POSTCODE NP22 4FF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 116
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-03-13
LOCAL AUTHORITY W06000019
CONSTITUENCY W07000084
COUNTY
LODGEMENT DATE 2016-03-16
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 115
ENERGY CONSUMPTION CURRENT 137
ENERGY CONSUMPTION POTENTIAL -93
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL -1.2
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 309
HEATING COST POTENTIAL 314
HOT WATER COST CURRENT 109
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 79
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 36
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.28 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 36% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 26, Walnut Close
LOCAL AUTHORITY LABEL Blaenau Gwent
CONSTITUENCY LABEL Blaenau Gwent and Rhymney
POSTTOWN TREDEGAR
CONSTRUCTION AGE BAND 2011
LODGEMENT DATETIME 2016-03-16 06:41:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10014120446
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew