Energy Performance Certificate

121 Sir Peter Blake Way, Alkerden, DA10 1HB

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 95 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 95 Current: 95 95 Potential: 95
Field Value
LMK KEY 9475-3908-2309-8534-7204
ADDRESS1 121 Sir Peter Blake Way
ADDRESS2 Alkerden
ADDRESS3
POSTCODE DA10 1HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2024-11-13
LOCAL AUTHORITY E07000107
CONSTITUENCY E14001191
COUNTY
LODGEMENT DATE 2024-11-13
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 95
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 53
ENERGY CONSUMPTION POTENTIAL 53
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 5.1
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 356
HEATING COST POTENTIAL 356
HOT WATER COST CURRENT 196
HOT WATER COST POTENTIAL 196
TOTAL FLOOR AREA 70
ENERGY TARIFF 24 hour
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.21 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 121 Sir Peter Blake Way, Alkerden
LOCAL AUTHORITY LABEL Dartford
CONSTITUENCY LABEL Dartford
POSTTOWN Dartford
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2024-11-13 14:19:57
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10096352214
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew