Energy Performance Certificate

52, Elliotts Row, SE11 4SZ

EPC Report

Energy rating

Current: 63 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 53 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 75 Potential: 75
Field Value
LMK KEY 9464-2811-7899-9598-3291
ADDRESS1 52, Elliotts Row
ADDRESS2
ADDRESS3
POSTCODE SE11 4SZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-11-19
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001085
COUNTY
LODGEMENT DATE 2018-11-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 201
ENERGY CONSUMPTION POTENTIAL 99
CO2 EMISSIONS CURRENT 6.3
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 1106
HEATING COST POTENTIAL 695
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 178
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, Elliotts Row
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Bermondsey and Old Southwark
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-11-20 21:35:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 50
UPRN 200003377685
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew