Energy Performance Certificate

30 Bricket Lodge, Lye Lane, Bricket Wood, AL2 3TF

EPC Report

Energy rating

Current: 47 E | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 44 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 74 Potential: 74
Field Value
LMK KEY 9463-2895-6629-9901-0831
ADDRESS1 30 Bricket Lodge
ADDRESS2 Lye Lane
ADDRESS3 Bricket Wood
POSTCODE AL2 3TF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2019-12-05
LOCAL AUTHORITY E07000240
CONSTITUENCY E14001507
COUNTY
LODGEMENT DATE 2019-12-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 716
ENERGY CONSUMPTION POTENTIAL 286
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 121
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 23
LIGHTING COST POTENTIAL 26
HEATING COST CURRENT 579
HEATING COST POTENTIAL 313
HOT WATER COST CURRENT 176
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 24
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 30 Bricket Lodge, Lye Lane, Bricket Wood
LOCAL AUTHORITY LABEL St Albans
CONSTITUENCY LABEL St Albans
POSTTOWN ST. ALBANS
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2019-12-06 08:56:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10024115104
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew