Energy Performance Certificate

10 Denton Court, 14, Cranes Drive, KT5 8AL

EPC Report

Energy rating

Current: 1 G | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 20 | Potential: 37
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 37 Potential: 37
Field Value
LMK KEY 9461-2818-7995-9628-6735
ADDRESS1 10 Denton Court
ADDRESS2 14, Cranes Drive
ADDRESS3
POSTCODE KT5 8AL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2018-11-28
LOCAL AUTHORITY E09000021
CONSTITUENCY E14001312
COUNTY
LODGEMENT DATE 2018-11-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 37
ENERGY CONSUMPTION CURRENT 887
ENERGY CONSUMPTION POTENTIAL 578
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 150
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 1755
HEATING COST POTENTIAL 485
HOT WATER COST CURRENT 299
HOT WATER COST POTENTIAL 132
TOTAL FLOOR AREA 39
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8.23
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Denton Court, 14, Cranes Drive
LOCAL AUTHORITY LABEL Kingston upon Thames
CONSTITUENCY LABEL Kingston and Surbiton
POSTTOWN SURBITON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-11-28 16:58:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100021786717
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew