Energy Performance Certificate

34, Pit Lane, Hough, CW2 5JQ

EPC Report

Energy rating

Current: 38 F | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 38 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 78 Potential: 78
Field Value
LMK KEY 9458-7088-7271-2874-7990
ADDRESS1 34, Pit Lane
ADDRESS2 Hough
ADDRESS3
POSTCODE CW2 5JQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-09-15
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001164
COUNTY
LODGEMENT DATE 2014-09-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 394
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 7.9
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1637
HEATING COST POTENTIAL 782
HOT WATER COST CURRENT 205
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 113
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34, Pit Lane, Hough
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Chester South and Eddisbury
POSTTOWN CREWE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-09-15 18:58:16
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 200001124968
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display