Energy Performance Certificate

22 Green Gage Gardens, CV37 9GE

EPC Report

Energy rating

Current: 97 A | Potential: 97 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 97 A Current: 97 A 97 A Potential: 97 A

Environmental impact (CO₂)

Current: 92 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 Current: 92 92 Potential: 92
Field Value
LMK KEY 9456-3053-9308-6335-7204
ADDRESS1 22 Green Gage Gardens
ADDRESS2
ADDRESS3
POSTCODE CV37 9GE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 97
POTENTIAL ENERGY EFFICIENCY 97
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2025-08-15
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001526
COUNTY
LODGEMENT DATE 2025-08-15
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 92
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 48
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 9.1
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 322
HEATING COST POTENTIAL 322
HOT WATER COST CURRENT 166
HOT WATER COST POTENTIAL 166
TOTAL FLOOR AREA 82
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.15 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.25 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 22 Green Gage Gardens
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Stratford-on-Avon
POSTTOWN STRATFORD-UPON-AVON
CONSTRUCTION AGE BAND 2023
LODGEMENT DATETIME 2025-08-15 11:34:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10094565818
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000005
Address display