Energy Performance Certificate

Aley Waymark, Aley, Over Stowey, TA5 1HB

EPC Report

Energy rating

Current: 68 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 66 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 74 Potential: 74
Field Value
LMK KEY 9446-3053-6208-6705-7200
ADDRESS1 Aley Waymark
ADDRESS2 Aley
ADDRESS3 Over Stowey
POSTCODE TA5 1HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-08-14
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001126
COUNTY
LODGEMENT DATE 2025-08-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 143
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 937
HEATING COST POTENTIAL 685
HOT WATER COST CURRENT 325
HOT WATER COST POTENTIAL 310
TOTAL FLOOR AREA 127
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.107
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Aley Waymark, Aley, Over Stowey
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Bridgwater
POSTTOWN BRIDGWATER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2025-08-15 07:09:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10013412141
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew