Energy Performance Certificate

203, Roche Court, NE38 7QS

EPC Report

Energy rating

Current: 87 B | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 105 | Potential: 106
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 105 Current: 105 106 Potential: 106
Field Value
LMK KEY 9436-2804-7593-9023-0875
ADDRESS1 203, Roche Court
ADDRESS2
ADDRESS3
POSTCODE NE38 7QS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE Bungalow
BUILT FORM End-Terrace
INSPECTION DATE 2017-11-24
LOCAL AUTHORITY E08000024
CONSTITUENCY E14001567
COUNTY
LODGEMENT DATE 2017-12-07
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 105
ENVIRONMENT IMPACT POTENTIAL 106
ENERGY CONSUMPTION CURRENT 133
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 440
HEATING COST POTENTIAL 392
HOT WATER COST CURRENT 86
HOT WATER COST POTENTIAL 40
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL biomass (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 30
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 203, Roche Court
LOCAL AUTHORITY LABEL Sunderland
CONSTITUENCY LABEL Washington and Gateshead South
POSTTOWN WASHINGTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2017-12-07 00:11:32
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 45123276
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000001
Address display
Nation ew