Energy Performance Certificate

77 Upgate, LN11 9HF

EPC Report

Energy rating

Current: 4 G | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 4 G Current: 4 G 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 18 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 85 Potential: 85
Field Value
LMK KEY 9429-2837-7101-9124-9161
ADDRESS1 77 Upgate
ADDRESS2
ADDRESS3
POSTCODE LN11 9HF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 4
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-10-23
LOCAL AUTHORITY E07000137
CONSTITUENCY E14001343
COUNTY
LODGEMENT DATE 2014-10-23
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 700
ENERGY CONSUMPTION POTENTIAL 82
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 124
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 2783
HEATING COST POTENTIAL 443
HOT WATER COST CURRENT 231
HOT WATER COST POTENTIAL 104
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 33
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77 Upgate
LOCAL AUTHORITY LABEL East Lindsey
CONSTITUENCY LABEL Louth and Horncastle
POSTTOWN LOUTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-10-23 09:20:02
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100030774161
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew