Energy Performance Certificate

70, Parc Pendre, SA17 4TE

EPC Report

Energy rating

Current: 52 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 44 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 87 Potential: 87
Field Value
LMK KEY 9424-2828-7723-9528-5481
ADDRESS1 70, Parc Pendre
ADDRESS2
ADDRESS3
POSTCODE SA17 4TE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-12-28
LOCAL AUTHORITY W06000010
CONSTITUENCY W07000098
COUNTY
LODGEMENT DATE 2018-12-31
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 376
ENERGY CONSUMPTION POTENTIAL 79
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 816
HEATING COST POTENTIAL 403
HOT WATER COST CURRENT 282
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 88
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 70, Parc Pendre
LOCAL AUTHORITY LABEL Carmarthenshire
CONSTITUENCY LABEL Llanelli
POSTTOWN KIDWELLY
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2018-12-31 02:59:24
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100100178667
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew