Energy Performance Certificate

1 Tallis Close, E16 3AY

EPC Report

Energy rating

Current: 77 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 81 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 81 Potential: 81
Field Value
LMK KEY 9420-2677-0079-7002-0673
ADDRESS1 1 Tallis Close
ADDRESS2
ADDRESS3
POSTCODE E16 3AY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Maisonette
BUILT FORM Semi-Detached
INSPECTION DATE 2026-03-23
LOCAL AUTHORITY E09000025
CONSTITUENCY E14001576
COUNTY
LODGEMENT DATE 2026-03-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 125
ENERGY CONSUMPTION POTENTIAL 125
CO2 EMISSIONS CURRENT 1.2
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 45
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 351
HEATING COST POTENTIAL 351
HOT WATER COST CURRENT 165
HOT WATER COST POTENTIAL 165
TOTAL FLOOR AREA 55
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR stairwell
UNHEATED CORRIDOR LENGTH 1.2
FLOOR HEIGHT 2.23
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Tallis Close
LOCAL AUTHORITY LABEL Newham
CONSTITUENCY LABEL West Ham and Beckton
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2026-03-24 10:06:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 46072997
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000007
Address display
Nation ew