Energy Performance Certificate

Fambridge House, Franklin Road, North Fambridge, CM3 6NF

EPC Report

Energy rating

Current: 27 F | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 27 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 64 Potential: 64
Field Value
LMK KEY 9407-3058-0202-9356-9204
ADDRESS1 Fambridge House
ADDRESS2 Franklin Road
ADDRESS3 North Fambridge
POSTCODE CM3 6NF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2026-02-10
LOCAL AUTHORITY E07000074
CONSTITUENCY E14001351
COUNTY
LODGEMENT DATE 2026-02-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 330
ENERGY CONSUMPTION POTENTIAL 130
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 5.7
LIGHTING COST CURRENT 205
LIGHTING COST POTENTIAL 100
HEATING COST CURRENT 3718
HEATING COST POTENTIAL 1613
HOT WATER COST CURRENT 671
HOT WATER COST POTENTIAL 276
TOTAL FLOOR AREA 189
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 94
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 42
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil, Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.53
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Fambridge House, Franklin Road, North Fambridge
LOCAL AUTHORITY LABEL Maldon
CONSTITUENCY LABEL Maldon
POSTTOWN CHELMSFORD
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2026-02-11 07:50:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 21
UPRN 100091256627
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew