Energy Performance Certificate

22, Dryden Crescent, ST17 9YH

EPC Report

Energy rating

Current: 35 F | Potential: 63 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 63 D Potential: 63 D

Environmental impact (CO₂)

Current: 32 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 52 Potential: 52
Field Value
LMK KEY 9401-2834-7793-9424-5715
ADDRESS1 22, Dryden Crescent
ADDRESS2
ADDRESS3
POSTCODE ST17 9YH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 63
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-11-24
LOCAL AUTHORITY E07000197
CONSTITUENCY E14001513
COUNTY
LODGEMENT DATE 2014-11-24
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 465
ENERGY CONSUMPTION POTENTIAL 278
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 1098
HEATING COST POTENTIAL 929
HOT WATER COST CURRENT 391
HOT WATER COST POTENTIAL 148
TOTAL FLOOR AREA 78
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Dryden Crescent
LOCAL AUTHORITY LABEL Stafford
CONSTITUENCY LABEL Stafford
POSTTOWN STAFFORD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-11-24 17:39:34
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100031765359
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew