Energy Performance Certificate

1, Bowland Close, DN5 9NG

EPC Report

Energy rating

Current: 64 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 61 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 79 Potential: 79
Field Value
LMK KEY 9391-2801-6629-9807-3425
ADDRESS1 1, Bowland Close
ADDRESS2
ADDRESS3
POSTCODE DN5 9NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-12-09
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001200
COUNTY
LODGEMENT DATE 2013-12-10
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 231
ENERGY CONSUMPTION POTENTIAL 125
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 665
HEATING COST POTENTIAL 565
HOT WATER COST CURRENT 104
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 84
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 73
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 73% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Bowland Close
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster North
POSTTOWN DONCASTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-12-10 10:54:51
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100050701385
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew