Energy Performance Certificate

12 Hartington Street, CA14 2NY

EPC Report

Energy rating

Current: 41 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 23 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 Current: 23 55 Potential: 55
Field Value
LMK KEY 9390-2159-8320-2327-3345
ADDRESS1 12 Hartington Street
ADDRESS2
ADDRESS3
POSTCODE CA14 2NY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-12-21
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001583
COUNTY
LODGEMENT DATE 2023-12-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 23
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 677
ENERGY CONSUMPTION POTENTIAL 312
CO2 EMISSIONS CURRENT 9.7
CO2 EMISS CURR PER FLOOR AREA 114
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 182
LIGHTING COST POTENTIAL 182
HEATING COST CURRENT 2869
HEATING COST POTENTIAL 1405
HOT WATER COST CURRENT 356
HOT WATER COST POTENTIAL 211
TOTAL FLOOR AREA 85
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 Hartington Street
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Whitehaven and Workington
POSTTOWN WORKINGTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2023-12-22 11:24:27
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100110233228
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000002
Address display
Nation ew