Energy Performance Certificate

31 Highfield Road, NG7 2JE

EPC Report

Energy rating

Current: 42 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 85 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 89 Potential: 89
Field Value
LMK KEY 9390-0756-0322-4292-3253
ADDRESS1 31 Highfield Road
ADDRESS2
ADDRESS3
POSTCODE NG7 2JE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-12-15
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001412
COUNTY
LODGEMENT DATE 2025-12-15
TRANSACTION TYPE Re-mortgaging
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 138
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 256
LIGHTING COST POTENTIAL 98
HEATING COST CURRENT 2845
HEATING COST POTENTIAL 1594
HOT WATER COST CURRENT 1126
HOT WATER COST POTENTIAL 442
TOTAL FLOOR AREA 142
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 97
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY 35
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31 Highfield Road
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham South
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-12-15 15:45:14
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT
UPRN 100031557585
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew