Energy Performance Certificate

8 RIALTON HEIGHTS, TR7 3HU

EPC Report

Energy rating

Current: 53 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 48 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 66 Potential: 66
Field Value
LMK KEY 9380-2917-2000-2004-6875
ADDRESS1 8 RIALTON HEIGHTS
ADDRESS2
ADDRESS3
POSTCODE TR7 3HU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2024-10-03
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001508
COUNTY
LODGEMENT DATE 2024-10-03
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 389
ENERGY CONSUMPTION POTENTIAL 252
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 916
HEATING COST POTENTIAL 441
HOT WATER COST CURRENT 229
HOT WATER COST POTENTIAL 229
TOTAL FLOOR AREA 46
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters, Room heaters, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.53
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8 RIALTON HEIGHTS
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Austell and Newquay
POSTTOWN NEWQUAY
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2024-10-03 14:55:12
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100040129794
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew