Energy Performance Certificate

125 Victoria Road, IG11 8PZ

EPC Report

Energy rating

Current: 72 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 71 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 88 Potential: 88
Field Value
LMK KEY 9380-2605-5490-2194-6455
ADDRESS1 125 Victoria Road
ADDRESS2
ADDRESS3
POSTCODE IG11 8PZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-11-15
LOCAL AUTHORITY E09000002
CONSTITUENCY E14001073
COUNTY
LODGEMENT DATE 2024-11-18
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 177
ENERGY CONSUMPTION POTENTIAL 53
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 100
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 535
HEATING COST POTENTIAL 445
HOT WATER COST CURRENT 139
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 70
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.53
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 125 Victoria Road
LOCAL AUTHORITY LABEL Barking and Dagenham
CONSTITUENCY LABEL Barking
POSTTOWN BARKING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-11-18 12:20:09
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100061872
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew