Energy Performance Certificate

18 Cranwell Crescent, Eaton Leys, MK17 9GT

EPC Report

Energy rating

Current: 98 A | Potential: 99 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 98 A Current: 98 A 99 A Potential: 99 A

Environmental impact (CO₂)

Current: 98 | Potential: 100
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 98 Current: 98 100 Potential: 100
Field Value
LMK KEY 9363-3003-9302-2102-5204
ADDRESS1 18 Cranwell Crescent
ADDRESS2
ADDRESS3 Eaton Leys
POSTCODE MK17 9GT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 98
POTENTIAL ENERGY EFFICIENCY 99
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-02-16
LOCAL AUTHORITY E06000042
CONSTITUENCY E14001141
COUNTY
LODGEMENT DATE 2022-02-16
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 98
ENVIRONMENT IMPACT POTENTIAL 100
ENERGY CONSUMPTION CURRENT 0
ENERGY CONSUMPTION POTENTIAL -10
CO2 EMISSIONS CURRENT 0.1
CO2 EMISS CURR PER FLOOR AREA 0.6
CO2 EMISSIONS POTENTIAL -0.1
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 252
HEATING COST POTENTIAL 252
HOT WATER COST CURRENT 70
HOT WATER COST POTENTIAL 44
TOTAL FLOOR AREA 99
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.15 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 18 Cranwell Crescent, Eaton Leys
LOCAL AUTHORITY LABEL Milton Keynes
CONSTITUENCY LABEL Buckingham and Bletchley
POSTTOWN Milton Keynes
CONSTRUCTION AGE BAND 2021
LODGEMENT DATETIME 2022-02-16 12:52:09
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 10095507027
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display